Chapter 11
Measure, cut, form, and integrate apron or headwall flashing at a roof-to-vertical-wall transition, coordinating the flashing with underlayment, wall drainage, and adjoining shingle courses so wall and roof water discharge onto the finished roof surface rather than behind it.
These cues appear at the point of work. They identify safety, code, manufacturer, and measurement issues before they become rework or hazards.
Task-specific safety guidance for ordinary work hazards.
Serious injury, fall, or major damage is possible.
Practical work-area safety: footing, weather, housekeeping, and access.
Local requirements vary. Verify permit, inspection, and jurisdictional rules.
Follow product-specific instructions for materials, fastening schedules, and equipment.
Slope, span, clearance, and reference-point guidance.
This chapter qualifies you to fabricate and install apron or headwall flashing at a roof-to-vertical-wall transition and to integrate it with the roof covering and wall-drainage layer in the correct shingle-lap order. The finished work product is one continuous, corrosion-compatible headwall or apron flashing assembly, dry-fitted, fastened, sealed at approved locations only, and photographed before wall finishes conceal it.
You will measure the headwall from fixed references, cut and form the flashing including end dams and corner returns, integrate the lower roof leg with underlayment and shingles in the manufacturer-controlled order, fasten only in approved locations, lap multiple sections correctly, integrate the wall leg behind the WRB, counterflashing, or cladding, and inspect the completed transition before it is covered.
This chapter builds directly on the roof-covering work established in Chapter 8 and the sidewall step-flashing method taught in Chapter 10. A headwall crosses the slope rather than running along it, so the flashing must carry water across the full width of the wall intersection in a single, continuous, laterally lapped assembly rather than as a shingle-by-shingle system.
Headwall and apron flashing depends on the deck, underlayment, and roof-covering work completed in Chapters 1, 5, and 8, and on the wall-drainage relationship taught alongside step flashing in Chapter 10. It must be integrated while the surrounding shingle courses are installed; it may not be inserted after the shingle field is complete unless an approved repair detail specifically permits it.
This chapter's flashing sequence feeds directly into later ridge, ventilation, and gutter work whenever a headwall condition is present on the Chapter 20 capstone structure, and it establishes the flashing-integration discipline used again in Chapter 12 for penetrations and in Chapter 18 for leak diagnosis.
This chapter covers:
This chapter does not authorize the learner to:
Any headwall condition that does not match the approved detail, or any wall assembly requiring counterflashing beyond this chapter's scope, must be referred to the responsible authority before the flashing is installed.
Establish these references before recording any measurement or cutting any metal, and use them consistently across the specification sheet and inspection record.
| Term | Definition |
|---|---|
| Headwall | A vertical wall surface that meets a roof plane across its slope, requiring flashing that carries water laterally before it drops onto the roof below |
| Apron flashing | The flashing piece at the base of a headwall that laps over the roof covering and turns up against the wall |
| Roof leg | The horizontal portion of the flashing that bears on and integrates with the roof covering |
| Wall leg | The vertical portion of the flashing that turns up the wall surface and integrates behind the WRB, counterflashing, or cladding |
| End dam | A formed upturn at the end of a flashing section that prevents water from running off the side of the flashing at a termination |
| Reglet / counterflashing | A wall-mounted receiving detail or overlapping metal component that covers the top of the wall leg |
| Kickout transition | The detail that directs water from a headwall or sidewall condition away from the wall and into the gutter or roof surface below |
Before beginning fabrication, record the controlling documents and location identification directly on the flashing documentation form:
Project / address: ______ Headwall detail revision: ______ Location on roof plan: ______
Date started: ____________ Installer name: ____________
A headwall is different from a sidewall. A sidewall runs along the slope and is flashed piece-by-piece with step flashing integrated course by course, as taught in Chapter 10. A headwall runs across the slope, so the flashing must be a continuous run (or a run of laterally lapped sections) wide enough to carry the full width of water arriving from above the wall. Getting the roof-leg and wall-leg relationship right, and keeping every lap oriented to shed water downslope and across the run in the approved direction, is the central skill of this chapter.
Integrate the lower roof leg with underlayment, membrane, and shingles in the manufacturer-controlled order so water from the wall drains onto the roof covering rather than behind it. Integrate the wall leg behind WRB, counterflashing, cladding, or trim components in the same shingle-lap sequence, maintaining the required clearance between roofing and siding or trim.
Headwall conditions often occur near dormers, additions, or upper-story wall intersections where the roof plane is narrow and the fall distance from the wall side may be greater than from the open roof edge. Confirm the roof-access and fall-protection system from Chapter 2 covers this specific location before working at the wall intersection.
Roof-leg width, wall-leg height, end-dam dimensions, and required laps are set by the approved headwall detail and flashing manufacturer's instructions. Do not shorten a leg or reduce a lap to fit an unplanned condition; stop and confirm the detail before cutting metal to a dimension not shown in the specification.
Do not bridge a designed drainage opening or weep path with sealant. Sealant is not a substitute for required flashing, laps, fastening, or drainage geometry. Verify which openings in the wall-drainage system are designed to remain open before applying any sealant near them.
RF-061 – RF-066
Flashing Fabrication / Integrated Installation
Deliverable: one continuous headwall or apron flashing assembly covering the full measured length of the wall intersection, formed with the specified end dams and corner transitions, dry-fitted, integrated with underlayment and shingles in the approved sequence, fastened only at approved locations, sealed only at approved terminations, and photographed before wall finishes conceal it.
| Document | Confirmed Current | Notes |
|---|---|---|
| Approved headwall / apron flashing detail | ||
| Flashing manufacturer's instructions | ||
| Underlayment and roofing-system specification | ||
| Wall WRB / counterflashing / siding-system detail | ||
| Chapter 1 roofing-readiness decision | ||
| Chapter 2 roof-access and fall-protection record |
| Check | Standard |
|---|---|
| Roof-leg coverage | Matches the approved roof-leg width across the full measured headwall length |
| Wall-leg height | Matches the approved wall-leg height and integrates behind WRB, counterflashing, or cladding |
| End dams | Formed at every required termination; no side-running water path at an end condition |
| Corner transitions | Formed without open gaps, reverse laps, or exposed unsupported metal |
| Multi-section laps | Meet the specified lap dimension and are oriented to shed water in the prevailing drainage direction |
| Fasteners | Located only in approved zones, out of primary water paths |
| Sealant | Present only at approved end joints, reglets, corners, or terminations; no bridging of designed drainage openings |
| WRB / cladding integration | Wall leg integrated in correct shingle-lap order with siding and trim clearance maintained |
| Documentation | Flashing material, dimensions, laps, fastening, sealant, and inspection results recorded and photographed before concealment |
Apply the same checks to every headwall or apron condition on the roof, regardless of length or corner count.
Complete the Headwall Flashing Inspection Record below before wall finishes are installed.
Probable cause: the roof leg was fastened over the underlayment rather than beneath it in the required order, or a lap between sections was reversed.
Confirmation: remove the minimum surrounding roofing needed to expose the roof-leg integration and lap direction at the suspect section.
Correction: restore the correct layering order and lap direction using the governing Chapter 18 leak-diagnosis procedure and the original headwall detail.
Reinspection: repeat the roof-leg coverage, lap-direction, and drainage-direction checks at the corrected section.
Probable cause: the corner piece was cut to a generic angle rather than the actual measured wall or roof-plane angle at that corner.
Confirmation: remeasure the actual corner angle and compare it to the cut and lap plan established in Step 4.
Correction: recut or reform the corner piece to the measured angle before proceeding to fastening.
Reinspection: repeat the dry-fit check at the corrected corner.
Probable cause: a fastener was driven through the roof leg in a location not identified as an approved fastening zone.
Confirmation: compare the fastener location to the approved fastening-zone diagram in the headwall detail.
Correction: remove the fastener, seal the resulting hole with compatible sealant only where the detail permits sealant at that location, and reset the fastening at an approved zone if additional securement is required.
Reinspection: recheck the corrected location for approved fastener placement and drainage continuity.
Probable cause: sealant was applied generally along the wall-leg termination without first identifying which openings are designed to remain open.
Confirmation: compare the sealed location to the wall-drainage detail and identify whether the opening is a designed weep path.
Correction: remove the sealant from the designed opening using a method that does not damage the wall-drainage component, and reapply sealant only at the approved locations identified in the detail.
Reinspection: confirm the opening is clear and functioning before the wall finish is installed.
Probable cause: the WRB or counterflashing installation sequence was completed before the wall-leg height was verified, leaving a gap at the top of the wall leg.
Confirmation: measure the installed wall-leg height and compare it to the approved detail and the WRB or counterflashing overlap requirement.
Correction: extend or replace the wall leg, or adjust the WRB or counterflashing lap, so the required overlap is restored before siding or trim is installed.
Reinspection: recheck the wall-leg-to-WRB overlap at the corrected location.
This chapter ends with a documented, photographed flashing assembly, not a pile of metal offcuts left on the roof or ground.
| Competency | Independent Pass Standard | Not Demonstrated | With Assistance | Independently |
|---|---|---|---|---|
| RF-061 | Measures headwall length, corners, and end conditions from defined references and records them accurately | |||
| RF-062 | Cuts and forms metal flashing to the approved profile using approved tools without damaging the coating | |||
| RF-063 | Installs apron flashing in the correct relationship to the roof covering and wall-drainage layer | |||
| RF-064 | Laps underlayment and adjoining shingle courses with the flashing in the correct shingle-lap order | |||
| RF-065 | Applies compatible sealant only at approved locations without bridging designed drainage openings | |||
| RF-066 | Inspects and documents the completed headwall assembly for coverage, laps, fastening, and drainage direction |
Mark one column per competency. Only Demonstrated Independently awards the competency; Demonstrated with Assistance authorizes additional supervised practice but does not complete the requirement.
| Item | Condition Found | Correction Required | Corrected (Y/N) | Reinspection Result |
|---|---|---|---|---|
| Roof-leg coverage | ||||
| Wall-leg height | ||||
| End dams | ||||
| Corner transitions | ||||
| Multi-section laps | ||||
| Fastener locations | ||||
| Sealant locations | ||||
| WRB / counterflashing integration | ||||
| Siding / trim clearance |
Flashing acceptance decision: ______ (Accepted / Corrections Required / Refer to Responsible Authority) Date: ____________ Inspector name: ____________
With the headwall flashing complete, review the Headwall Flashing Inspection Record against the Acceptance Standards table and confirm the roof-leg and wall-leg dimensions match the approved detail, every corner and end dam is formed without a gap or reverse lap, every fastener is located in an approved zone, sealant appears only at approved terminations without bridging a designed drainage opening, and the wall leg is fully integrated behind the WRB or counterflashing. Photograph the completed assembly and record dimensions, laps, fastening, and sealant locations before wall finishes are installed.
You have completed the headwall and apron flashing chapter: measuring, fabricating, and integrating a continuous flashing assembly at a roof-to-wall transition. This chapter required you to measure headwall flashing from defined references (RF-061), cut and form metal flashing to the approved profile (RF-062), install apron flashing in the correct relationship to the roof covering and wall drainage layer (RF-063), lap underlayment and shingles with the flashing in the correct order (RF-064), seal exposed transitions only at approved locations (RF-065), and inspect the completed assembly for coverage, laps, fastening, and drainage direction (RF-066).
You now have a continuous, documented headwall flashing assembly integrated with the surrounding roof covering and wall-drainage layer. That record carries directly into the next chapter: flashing a plumbing vent or other roof penetration using the same integration discipline established here.
Store the completed flashing documentation and photographs with the project record. Chapter 18 references this record if a leak is later diagnosed near this wall intersection.